Specifications include, but are not limited to: Control Panel is equipped with the following: -Individual relay and breaker for each valve (class 2 circuit output) -Built in CFCI protection -Self-programing of 3 different valve sequences with adjustable overlap timers -A pre-flush sequence -Manual operation of the HMI -A 7-day timer -A control power transformer -An output power supply -An output terminal strip -A hand-off-auto switch and a door disconnect. The Control Panel may also be equipped with some or all of the following devices: -Motor starters -Variable frequency drives, -24 hour timers -Run lights and ground fault circuit protection. Additionally, each project has unique features that may require additional electronic components that may be installed in the Controller. The Programmable Logic Controller Windows based screen for a PC that allows the operator to make changes easily by changing timelines (timing for individual water features) and enabling or disabling individual water features with on/off buttons. The program allows the operator to go into program, monitor or run mode. Program mode allows changes to the program itself...