Specifications include, but are not limited to: The Dual Throat Wet Air Scrubber shall be designed to efficiently remove airborne particulate using a nonplugging, manually adjustable scrubbing throat. The small water droplets created by the venturi contact the airborne particulate creating a heavier mass to be centrifugally removed by the dropout, baffles, and mist eliminator section. The scrubber shall utilize up to 15 gpm of water provided at 45 psig. Spent liquid shall be collected in the scrubber pyramid hopper and drain by gravity to the existing tank. A direct drive fan assembly shall be mounted to the scrubber outlet. The design criteria and requirements of the Dual Throat Wet Air Scrubber are as follows: a) Design Capacity: 2500 ACFM b) Design Temperature: 140 ºF c) Relative Humidity: no limit d) Maximum System Dimensions: 5' 6" W × 5' 6" L × 12' 6" H e) Approximate Operating Weight 1800-2000 Lbs. f) External Static Pressure Required: 15 inches W.C. for customer duct (6 inches W.C. Internal pressure) g) Required Scrubber Performance: 95% removal of 5 µm particulate and larger h) 304L Stainless Steel Construction i) Mist eliminators - High Density Polyethylene