Specifications include, but are not limited to: 1. Opening a. Doors to be installed in opening of approximately 22’ 11 ½” X 13’ 8” – Measurement to be verified by Contractor prior to bid and/or installation – site inspection available Monday thru Thursday 6:00 am to 3:30 pm 2. Mounting a. Right- Concrete, Between Jambs b. Left- Concrete, Between Jambs c. Lintel- Concrete d. Header- Concrete 3. Curtain a. Curtain: Interlocking roll-formed slats (non-insulated) b. Endlocks shall be attached to each end of alternate slats c. Curtain to be of 20 gauge galvanized steel construction d. Curtain Interior, mounted above Lintel e. Wind load – Standard 20 PSF f. Curtain to have Curved Slat Profile C-275 measuring 2 ¾” in height x 7/8” wide g. Curtain wrapped on pipe h. Curtain to have Prime coat applied – 0.2 mills thick baked-on prime paint i. Top Coat 0.6 mils thick, baked-on Manufacturers standard white finish 4. Pass Thru Door a. Integrated Pass Thru Door b. Left Side, Door opposite Coilside c. Pass door closer 5. Operation a. Motor to be supplied by Manufacturer b. Motor to be UL listed c. Motor must meet or exceed all Local, State and Federal Code Requirements for Electric Motors d. Motor to be mounted Front of Hood, Right Hand 6. Operator a. Model RSX or Equivalent b. Standard Duty c. ¾ Horsepower d. 115/208/230 Volt Single (1) phase sixty (60) Hertz e. No Entrapment (Constant Contact) f. Twenty four (24) Volt DC Brake System g. Receiver System h. Auto-tensioning Belt i. Clutch, Adjustable Disc type.