Specifications include, but are not limited to: 1.0 PROCEDURE 2.0 Repair any damage to the substrate, remove any exposed or erupted fasteners, and clean thoroughly in preparation to receive the roof system. 3.0 Where seams exceed 2” in height, install cant strips at each seam. 4.0 Apply Seamless roof membrane materials to provide a watertight roof assembly that meets WeatherWeld warranty requirements. Encapsulate entire roof area. 5.0 Install Flashings and Accessories. 6.0 Install Walkway pads (where applicable). 7.0 Apply Anti-Skid Traffic Coating (where applicable). 8.0 ADMINISTRATION A. Refer to local laws and building code for thermal value requirements, wind uplift, and other requirements. B. Refer to Manufacturer installation manual, detail drawings, and specific industry guidelines for good work practice procedures. C. Follow all recommendations referenced in the current edition of NRCA roofing and Waterproofing Manual. D. Wind Uplift Rating Required: I-90 E. Fire Rating: UL Class A 9.0 ROOF INSPECTION A. Provide written documentation to owner to replace wet/damaged roofing materials or decking. B. Installer is responsible to ensure no ponding water exists after 48 hours after precipitation. 10.0 PROTECTION OF WORK A. Protect all areas from material spills and overspray with appropriate masking. B. Protect adjacent areas from vehicle or equipment staging damage. C. All areas not specified for roofing material installation must be clean and free of material drips or overspray before project is considered complete. 11.0 GENERAL REQUIREMENTS AND BEST PRACTICES A. Ensure all surfaces are clean, compatible, dry, free from debris and sharp projections, dirt, grease, etc. before installing roofing materials. B. Install asphalt primer to facilitate proper adhesion at flashings, walls, and other rooftop components. C. Ensure roof is washed between steps to ensure adequate adhesion. D. Contractor is responsible to ensure no ponding water exists when the project is complete.