Specifications include, but are not limited to: 1. TS2 Type 1 "P" base mount cabinet Assembly, "P" base mount 56"H x 44"W x 28"D, and natural aluminum finishes outside and inside. A. One shelf has a sliding drawer. B. Shelves are placed to provide the optimal viewing angle of the controller's display. C. The Neutral connecting bars are to be placed on the cabinet's left, center, and right sides. D. Chassis ground connecting bars placed on the left and right sides of the cabinet. E. Outward rotating door handle. F. Double flanged door frame and continuously welded seams to maximize the protection of signal equipment housed from weather elements. G. The cabinet includes lifting ears. 2. 16 Position load bay with full load switches a. (two) terminal facility BIU's if 16 channels, otherwise (one) BIU and 1(one) Detector BIU 3. 16 channel: Wired for eight (8) phase NEMA controller with four (4) overlaps and four (4) pedestrian 4. All load resistors are to be removable from the front panel. 5. Cabinet includes a standard dual circuit solid state NEMA flasher to flash phases 2 and 6 amber and all other phases red.