Specifications include, but are not limited to: For the purpose of this project, the Proposer should assume that all existing electrical infrastructure (conductors, electrical panels, breakers, etc.) are in good working order, and only fixture and/or lamp replacement is required. The Proposer shall be responsible for any mounting adjustments necessary for installation of new fixtures in a manner consistent with their existing condition. New fixtures shall match the existing fixture color. a. Retrofit all existing non-LED fixtures (lamp for lamp) throughout the work area with ballast bypass LED lamps. Ballasts to be disconnected with this scope of work as required. b. All quantities provided are approximate – fixture and lamp counts to be verified by Proposer. c. If a fixture cannot be retrofit, then it will need to be replaced with like size, shape, and finish. d. All lighting must be equivalent to or greater than the existing lighting output. e. All lighting installed on the interior will be 4000 Kelvin. f. Proposer to verify quantity of fixtures and lamps in the designated in Exhibit A