Specifications include, but are not limited to: Vendor is to complete pricing below to include all costs associated with the below services as stated herein including labor, materials, preparation, equipment, chemicals and PPE. Please refer to Attachment A for the project manual. 25.1 All asbestos removal for this specific project are located inside the lobby and 2nd floor joint compounds and cross-contaminated sheetrock walls and ceilings at 930 Third Street Rosenberg TX 77471. 25.2 The lobby debris pile will be barricaded off and all asbestos-containing non-friable black mastic and tiles totaling approximately forty (40) square feet will be placed in asbestos labeled waste disposal bags. Personnel will wear proper PPE while performing this work. 25.3 The 2nd floor hallway and room will be a single negative pressure asbestos removal containment will be used for asbestos removal totaling approximately one-hundred fifty (150) square feet of RACM. Any remaining stationary items with be covered with polyurethane by the Asbestos Abatement Contractor. All removals will be conducted under negative pressure full containment methods. Allow for negative air machines ductwork to exhaust to the outside air. 25.4 The NESHAPS interior asbestos-containing joint compounds and cross contaminated sheetrock walls and ceilings category is RACM and will be removed in a single negative pressure containment. When the asbestos-containing sheetrock joint compounds become subject to abrading, crumbling, or pulverizing materials equates to the asbestos-containing RACM. All asbestos removals for this specific project are located inside the Movie Theater building lobby (debris pile) of asbestos-containing black mastic on tiles (exterior type) and 2nd floor joint compounds and cross-contaminated sheetrock walls and ceilings will be removed by the Asbestos Abatement Contractor. The lobby debris pile will be barricaded off and all asbestos-containing non-friable black mastic and tiles totaling approximately forty (40) square feet will be placed in asbestos labeled waste disposal bags. Personnel will wear proper PPE while performing this work. The 2nd floor hallway and room will be a single negative pressure asbestos removal containment will be used for asbestos removal totaling approximately one-hundred fifty (150) square feet of RACM. Any remaining stationary items with be covered with polyurethane by the Asbestos Abatement Contractor. All removals will be conducted under negative pressure full containment methods. Allow for negative air machines ductwork to exhaust to the outside air. The NESHAPS interior asbestos-containing joint compounds and cross contaminated sheetrock walls and ceilings category is RACM and will be removed in a single negative pressure containment. When the asbestos-containing sheetrock joint compounds become subject to abrading, crumbling, or pulverizing materials equates to the asbestos-containing RACM. All work will be performed in accordance with these written Asbestos Abatement Specifications and is classified as OSHA Class II Asbestos Work, therefore all work will be conducted under negative pressure containment utilizing 6 mil polyethene, proper PPE, wet removal methods, attached and functional wet decontamination unit, visual clearance and meet final air clearance criteria. All acm waste will be contained in disposal bags, manifested and transported to an approved landfill. The waste disposal requirements are further defined within these specifications. The Asbestos Abatement Contractor will be responsible for relocating and securing movables to an area not being abated in order to conduct the abatement.