Specifications include, but are not limited to: ULTRAVIOLET MODULES Trojan’s Responsibility: Each module supplied shall be completely assembled containing lamps, quartz sleeves and be electrically wired to each electronic ballast. Modules are shipped in a support rack and crated. Model and Make: Standard System TrojanUV3000PlusTM Quantity: Sixteen (16) UV modules each containing four (4) UV Lamps Material of Construction: 316 stainless steel frame Approximate Weight: 84 lbs per UV module SYSTEM CONTROL CENTER Trojan’s Responsibility: One (1) System Control Center (SCC) shall be supplied to monitor and control the UV System. Trojan will provide a PLC I/O and soft address map to aid the Contractor with integration of the UV PLC and WWTP SCADA system. The UV SCC shall consist of the following: Quantity Supplied One (1) SCC Location: Wall mounted (by others) Controller Type: Allen-Bradley CompactLogix (5069-L320ER) PLC Operator Interface: 12” Beijer HMI - Type 4X (Outdoor rated) Panel UPS: 30 Min on 24VDC Enclosure Material/Rating: 304 Stainless Steel - Type 4X (IP66) Approximate Weight: 200 lbs Installation Contractor’s Responsibility: The Installation Contractor is responsible for mounting the SCC as indicated on the drawings. The Installation Contractor is responsible for the supply, installation and connection of the following at the SCC: 1. One (1) 120V, 60 Hz, single phase, 2 wire + Gnd, 1.44 kVA power supply. 2. One (1) 4 – 20 mA DC analog signal from plant flow meter. 3. One (1) Ground Link , 14 gauge minimum type TWH stranded, daisy chained to the HSC and PDCs. 4. One (1) serial communication link consisting of one (1) shielded twisted pair, 18 gauge maximum from the HSC and other PDCs (daisy chained). 5. Discrete signals from Plant SCADA for remote monitoring (or serial communication link to SCADA via Ethernet IP protocol). POWER DISTRIBUTION CENTERS Trojan’s Responsibility: The Power Distribution Center (PDC) distributes power to the UV Modules and shall consist of the following: Quantity Supplied: Four (4) PDCs Enclosure Material/Rating: 304 Stainless Steel - Type 4X (IP66) Approximate Weight: 220 lbs per PDC Installation Contractor’s Responsibility: The Installation Contractor is responsible for setting in place and bolting the Power Distribution Centers to the top of channel. The Installation Contractor is also responsible for the supply, installation and connection of the following at each of the Power Distribution Centers (PDCs): 1. One (1) 208V, 60Hz, 3 phase, 3 wire + Gnd, 4.10 kVA power feed with local disconnect 2. One (1) Ground Link,14 gauge (2.5mm²) minimum, TWH stranded single wire from the HSC. 3. One (1) communication link consisting of one (1) shielded twisted pair from the SCC and daisy chained to other PDCs. 4. One (1) pair 24Volt DC, 18 guauge minimum power feed to the Level Control Panel from the two PDCs in the channel. 5. One (1) pair of 24Volt DC, 18 gauge (1mm²) minimum discrete signal to the water Level Control Panel to each of the two PDCs. 6. Connection of communication, power cables and hydraulic lines from the UV Modules