Specifications include, but are not limited to: include installing a total of 3 interior doors and 3 exterior doors. All equipment shall be compatible and work with Genetec and will need to be Wiegand. This scope of work will include all hardware associated with the access control installation. I prefer to use Axis Door Controllers for these doors. This location will also get 5 Axis Cameras installed. Models and locations are below in deliverables. Out of Scope 1. All configuration of the cameras and locks in Genetec will be done by the System Security Officer. 2. Only installation of Lock hardware and Cameras will be done by contractor. Deliverables LOCKS 1. Complete the installation of the electrified door strikes for external and Internal doors. a. Install electrified locks or Mag locks on Exterior glass doors (3 doors). i. Contractor will need to look at doors to determine the best method of lock, being electrified cylinder or mag lock. ii. One door in the front is a glass double door iii. One door in the font is a single solid door iv. One door in the back is a solid door. b. Install electrified locks or Mag locks on 3 interior doors. i. These doors include the dividing door between Adult and Juvenile Justice departments. This door is a solid wood door. ii. Door between waiting area and back area on the Adult Justice side. iii. Door between waiting area and back area on the Juvenile Justice side. 1. Both of these doors are solid wood doors c. All doors will need to be connected to Axis Door controllers and Door controllers will need to connect to Genetec Cloud link. d. The two Front doors will get Axis A8207-V MkII Doorstations for their card readers. e. The Back employee entrance will get a standard Card Reader f. Connect and power the electrified locks and test. g. Installer shall provide a wiring diagram for all locks, sensors and readers. i. (We will need this for when we configure the locks) CAMERAS 1. One Axis M2036-LE Camera will be installed and mounted on the East side of the building above and to the left of the back door. 2. Network cabling will need to be pulled for all cameras back to the Network Closet. Cable needs to be industry standard Cat6a.