Specifications include, but are not limited to: A. The following specifications are for a Foxboro Model 9500A, IP68 Magnetic Flowmeter, including: 100' Potted Cable, Grounding Rings, Model IMT31A Wall Mount Transmitter. 1. Liner material shall withstand varying water conditions present. 2. Self-grounding flow tube. Must operate without separate grounding ring. 3. System Accuracy digital communication 0.5% at > 2 fps 4. Low flow cut-off all indications set to zero below 0.04 fps 5. Maximum flow 33 fps 6. Ambient temperature effect ±0.25% change over operating temperature range 7. Repeatability ±0.1% of reading 8. Minimum Liquid conductivity 20 µS/cm 9. Power 110 VAC 60 Hz nominal 10. Flow transmitter housing NEMA 4X splash-proof will be mounted outdoors. 11. Temperature 20ºF to 150ºF 12. Directional indication by display, digital communication and contact closure 13. Operating range of 200 gpm to 50 mgd according to size 14. Damping setting between 0.1seconds and 30.0 seconds 15. Flow tube shall be flanged AWWA150. Nominal operating pressure is 150 psi 16. The flow transmitter will be mounted up to 100 feet from the flow tube. The transmitter shall be certified for installation in hazardous areas. 17. The flow transmitter shall be capable of 4-20 mA operation and at a minimum Hart communication. Other communication methods and protocols are of interest but not binding in the specification. Security lockout method will protect configuration variables from unwanted or accidental change. B. Meter Locations 1. North Topeka groundwater water well discharge. 4 inch. Installed in meter pit. Potential submersion. Kansas Department of Agriculture certification. Transmitter outdoors under sun shade. 2. Oakland Wastewater Treatment Plant process treatment. 24 inch. Installed in vault. Potential submersion. Transmitter outdoors under sun shade. 3. Central Park Pump Station. 10 inch. Installed in dry well. Transmitter installed on motor control room wall. 4. Central Park Pump Station. 16 inch. Installed in vault. Potential submersion. Transmitter installed on motor control room wall. C. The successful bidder shall provide startup services for the meters. The services will include but not be limited to, instrument documentation, configuration to owner requirements, certification of factory authorized setup compatible with Kansas Department of Agriculture procedures.