Specifications include, but are not limited to: Qty:1 - Oxygen Transmission Rate Analyzer for film and packages: (Basis of specification Manuf: Mocon, Make/Model: Ox-Tran 2/22) • Minimum of two test cartridges (sample holders) that can be removed easily for sample loading. • Ability to seal sample to test cartridge with technology that prevents edge seal leaks that cause testing failure. • Meets Standards: ASTM D3985, F1307 & F1927, ISO 15105-2, JIS K 7126-2, DIN 53380-3, GB/T 19789-2005, GB/T 31354-2014 • Uses coulometric sensor with a sensitivity range of 0.05 to 200 (cc/m2*day) @ 100% oxygen with sample size of 50cm2. Able to directly measure 100% oxygen without calibration since it is a direct method of measurement with humidified sensor. • Resolution of 0.02 cc/m2*day • Repeatability of 0.02 cc/m2*day or 1%, whichever is highest • Internal calibration not needed each time a test is performed and no Individual Zero value needed. • Built-in touch screen controller so an additional separate computer is not needed. (selfcontained unit for running the equipment). • Able to run in a RH range of 0-90% • Able to perform testing within a range of 10-40oC • Sensor lifespan (3-5 years) with built-in Over-range Protection • Able to run independent of temperature, pressure and flow so results are not affected by ambient conditions • Ethernet and USB ready, Capable of remote monitoring and controlling • Start-up kit included with package testing adaptor and standard test films. Qty: 1 - Water Vapor Transmission Analyzer for film and packages: (Basis of specification - Manuf: Mocon, Make/Model: Permatran-W 3/34) • Minimum of two test cartridges (sample holders) that can be removed easily for sample loading. • Ability to seal sample to test cartridge with technology that prevents edge seal leaks that cause testing failure. • Modulated infrared sensor which measures water vapor permeation in a range of 0.005 to 100 g/(m2*day). At least 4-year warranty on sensor. • Complies with standards: ASTM F1249, ISO 15106-3,JIS K-7129, TAPPI T557, GB/T 26253-2010 • Built-in touch screen controller so an additional separate computer is not needed. (selfcontained unit for running the equipment). • Able to run in a RH range of 5-90% • Able to perform testing within a range of 10-40oC • Automatic controls for RH, temperature, pressure and flow of both carrier and test gasses • Test modes include fully automatic, advanced and sequential. • Ethernet and USB ready, Capable of remote monitoring and controlling