Specifications include, but are not limited to: -Contractor shall install four LCN 9540 (or equivalent) reverse electromechanical door openers. -Two shall be installed on building #20 Transitional Family Life Center; one at the front entrance and one at the back exit door. -One shall be installed on building #21 Transition building entrance door. -One shall be installed on building #6 Cafeteria door facing the playground. -Contractor shall move existing card readers for residents to be able to access. -Two card readers are to be moved on building #20 Transitional Family Life Center at the front entrance and the back exit door. -One card reader relocated on building #21 Transition building entrance door. -One care reader relocated on building #6 Cafeteria door facing the playground. -Contractor shall install one Brivo ACS6100 regular expansion chassis (current system is a Brivo) in the nurse’s station in building #20 Transitional Family Life Center. -Expansion chassis system shall include the following components: Install one regular enclosure with lock Install one B-ACS6100-PSB internal power supply board Install one Plug-in AC/C power adapter Install one 12v 14Ah sealed lead acid battery backup Install one Single gang tri-technology reader with keypad (black enclosure) Install one Two-reader expansion board with OSDP -Contractor shall install one modular Strike for Mortise and cylindrical lockset, stainless steel, satin, field selectable voltage 12 or 24vdc and 12 volt to 24VAC. -Contractor shall run compatible wire from Transitional Family Life Center building #20 to Transitional gym building #21 in order for nurse’s station card reader to work. -Contractor shall perform a system test to make sure all equipment is functioning properly.