Specifications include, but are not limited to: 1. North Charleston Community Center Pool a. Equipment: Two Pulsar Solenoid DC valves – system 45, 140, 500 One Pulsar acid feeder venturi One Pulsar dry acid feeder system Four Unions (quick disconnect) venturi )slip xthread 1 ½ inch. One 2.6 THP 115/208/230V WHISPERFLO VST IG PENTAIR Booster PUMP One emergency shutoff valve (HCE ESV ASSEMBLY) One complete assembly w/ check valve kit (NEW STYLE) One check valve for discharge arm One BECs needle valve & flowmeter upgrade kit One BECs PH Sensor – 36” cable One BECs ORP Sensor plat band 36-inch cable One BECs 6-inch Magmeter (10 inches – 36 inches) One BECs 6-inch PVC Clamp on Saddle One BECs CP – 1 sensor w/ beads and o-rings. b. Installation: Vendor will install all equipment and re-pipe booster pump to work with dual venturi setup, confirm system operation and train City of Charleston Parks and Recreation employees on how to operate the new system setup. 2. Kanawha City Community Center Pool a. Equipment: Two Pulsar Solenoid DC valves – system 45, 140, 500 One Pulsar acid feeder venturi Four Unions (quick disconnect) venturi )slip xthread 1 ½ inch. One 2.6 THP 115/208/230V WHISPERFLO VST IG PENTAIR Booster PUMP One emergency shutoff valve (HCE ESV ASSEMBLY) One complete assembly w/ check valve kit (NEW STYLE) Two check valve for discharge arm One Stepdown 24 VDC Transformer for ORP Kit One 24 VDC Solenoid for SDCH ORP Kit (24 VDC Brass) One BECs PH Sensor – 36-inch cable One BECs ORP Sensor plat band 36-inch cable One 6-inch x 5-inch Reducing Concentric Strainer One Spare Strainer Basket Two BOLT KIT 5–8-inch FTF SS Bolt Pack for Strainer Four 4-inch BUTTERFLY VALVE S30,WAFER/175 MAX PSI with Level Handle Four 6-inch BRAY BFV SERIES 30 WAFER STYLE/175 MAX PSI with Lever Handle Four BOLT KIT 4-inch FVF SS Butterfly Valve Four BOLT KIT 5-8-inch FVF SS Butterfly Valve b. Installation: Vendor will provide services to install all equipment and re-pipe booster pump to work with dual venturi setup, replace strainer, SS hardware, and filter valves listed, confirm system operation and train City of Charleston Parks and Recreation employees on how to operate the new system setup.