Specifications include, but are not limited to: 1. Remove existing shingles and underlayment down to roof deck. 2. Inspect all wood decking for any deficiencies, such as wood rot or decomposition, valleys, humps, shrinkage, etc. a. All damaged wood shall be replaced with new OSB matching the existing dimensions. b. Secure all loose wood on the roof deck. 3. Provide and install the following: a. Owens Corning WeatherLock 3’ x 66.7’ Granulated Self-Sealing Ice and Water Barrier at all gutter lines, valleys, pipe jacks and areas required per manufacturer specifications. b. Tyvek Protec 120 synthetic underlayment using one inch (1”) cap nails. c. New aluminum drip edge. d. GAF, Owens Corning, Malarkey, or CertainTeed thirty (30) year 3D architectural asphalt shingles per manufacturers specifications using one and one quarter (1 ¼”) coil roofing nails. i. Preferred color is black onyx; Owner shall approve final color based on manufacturer selected. e. Starter shingles along all gutter lines and rake edges. f. New ridge vent or power vent dependent on application and ventilation requirements. g. Proper ridge shingles. h. New pipe flashing (boots) and paint exhaust pipes to match the shingle color. i. New chimney flashing, step flashing, and counter flashing per manufacturers specifications. 4. Clean Project site of all debris, including the running of magnets in landscaping, driveways, and surrounding areas. 5. Provide one (1) year workmanship warranty and manufacturers standard material warranty.