Specifications include, but are not limited to: The bidder shall submit a project plan using the design standards below that is in compliance with all applicable HUD, EPA, and State of Illinois regulations as well as all local building and zoning codes. The plan must include a clear project timeline and budget with line item costs. The contractor shall act as the general contractor for the project using subcontractors as required. Subcontractors that will be required should be clearly identified in the project plan. 1. Remove existing brick chimney down below the roof line. Reconfigure the flu coming out of the chimney to meet 2015 IMC. Install framing to support the new sheathing patch. Flu pipe will need an approved roof flashing, storm collar and cap. 2. Remove existing shingles down to sheathing. Check over all the existing roof sheathing for any water damage, broken boards, and larger then ½” gaps between sheathing replace as needed. If a sheath over is required a change order must be okayed by the Construction Officer before continuing. Patch the existing holes from the turtle/can vents. Remove the sheathing at the ridge per shingle over vent manufactures directions. Install ice and snow guard around the lower section of roof making sure to cover at least a 1 ft over top plate on the exterior walls below. Installed approved water barrier over the remainder roof. Install 30-year architectural shingles homeowners’ choice of colors. New shingle over ridge vent. New plumber boots over the vents and split ring for the mast flashing. New 2” white style D roof edge. Permit required before work starts. 3. Repair existing white vinyl siding on the front gable with matching locking systems and color as close as possible match. Some of the siding needs engaged as well. 4. Remove existing basement stairs. Install new set stairs with tread, risers, and 3 stringers. This stair system may not be able 2015 IRC applicable due to existing stair well opening. Modifications will be needed to achieve the stair system close to building codes as possible. Handrailing must be installed.