Specifications include, but are not limited to: 1. The Successful Bidder shall be responsible for drilling and sealing all holes in walls and partitions. 2. Where possible, all station wiring shall be concealed in existing conduit, crawl space or attic. When it is only practical to surface mount cabling, it shall be enclosed in wire mold or plastic covering. 3. A 3/4" fire retardant plywood backboard shall be supplied by the Successful Bidder for mounting the KSU (Key Service Unit) and all punch blocks. This backboard shall be securely mounted on the wall of the telephone equipment room. 4. All installation hardware and cable shall be new. Single station cables shall be four twisted pairs and/or two more twisted pairs than used actively in the system design. 5. All cables shall be Teflon jacketed and/or plenum rated where run in air plenum areas or required by the Building and Fire Codes of the County. 6. All installation work shall be done utilizing generally accepted telephone industry installation practices. 7. The Successful Bidder shall agree to comply with all Local, State, and Federal codes in regard to the installation of materials and labor as outlined in this IFB and is responsible for securing and paying for necessary permits as part of the Bid price. 8. All interconnecting cables, station cables, and any other wiring shall be clearly labeled. A complete cable running list shall also be submitted and made part of the installation documents. 9. The Successful Bidder shall be responsible for making the cross- connections from the Verizon Telephone Company Interface to our equipment. 10. The Successful Bidder shall coordinate with other contractors as is necessary at his own expense for any supporting trade work he may require...