• The demolition /removal of all existing plaster and tile from the entire pool surface. • Installation of a new Hydrazzo Gulf Stream Blue plaster surface, • Installation of new Hydrostatics Relief valves • Installation of new tile *Lane and target tiles *Deck and Mounted Depth and NO Diving tile • Visually inspect all pool structural areas for problems including pool shell, gutters, and surge tank. Report any problems to Associate Director to discuss options for any needed repairs. • Inspect all underwater pool lights and discuss options with Associate Director to replace any defective bulbs or lighting hardware with high-quality products like the Pentair LED lights and ensure that all lights and hardware are reinstalled and reset and functioning properly. • All surface cracks should be repaired using Qwik Joint 300 high performance polyuria joint filler and joint repair material made by the Euclid Chemical Company according to the manufacturer’s recommendations. • The joint between the gutter and the pool shell should be cleaned and caulked with High Chlorine Resistance Sikasil Pool Silicone Sealant.