Specifications include, but are not limited to: The system shall be a fixed tilt (35-40 degrees) ground mount racking, as opposed to single or dual-axis tracking. For foundation TCC prefers either driven posts (aka. Driven pile, driven beams, Hbeams, or I-Beams), or helical piers for the solar foundation design. Refer to Geo-technical survey completed at site for data to determine embedment depths (provided in attachments). Selected racking company is expected to have an Alaskan PE on staff who is able to stamp the recommended design based off of the attached geotechnical analysis. TCC has a 95% design of the 1.183 MW Solar Array (provided in attachments). Solar Modules to be designed around are SEG 550 W, Yukon Series(provided in attachments). Engineered structural drawings of racking structures must be provided by racking manufacturer.