Specifications include, but are not limited to: The City of Pikeville is accepting bids for the purchase and installation of a Fire Training Facility (Burn Room). The reference fire training facility should consist of two (2) “shipping” containers. The containers are to measure, Container (1): 40’ x 8’, Container (2): 20’ x 8’. The two containers are to be located on a suitable concrete foundation for the facility. Container (1) should be located West to East. The Westerly portion of the container should include a door opening which connects container (1) to the existing burn facility (door already installed). There should be a door located at the midway point of the on the Northside of the container. On the Easterly portion of the container there should be a 8’ x 8’ insulated burn apron made of high temperature panels and floor and a thermal door combining containers (1) & (2) (see below). Container (2) should be located West to East. Container (2) should include a 20’ x 8’ insulated burn room made of high temperature panels and floor, as well as a thermal burn door, located on the West wall. There should be 3 floor drains located in this container with clean out chutes. Located near the Southeast wall should be a clean out hatch for the removal of products within the container. The interior and exterior of each container should be painted. Color to be determined prior to painting.