Specifications include, but are not limited to: This SOW is for access control to be installed at our JW SAM One Stop Shop building in Catoosa Ok, at 701 W Rollins St. This SOW will include installing a total of 4 exterior doors, and 12 interior doors. Equipment shall be compatible and work with Genetec. Life Safety Power Cabinets with dual power supplies with Mercury Systems 10 boards is preferred, with LP4502 and MR52. The LP4502 will be used only for card control and cabinet tamper switch, system will run at 12VDC. The external doors are double door. 10 of the interior doors are solid double doors and 2 are single doors. This scope of work will include all hardware associated with the access control installation. There are currently a few doors that are on access control at this location, but I would like to keep this installation separate, meaning that these doors will use their own controllers and Cloud links or any other hardware. We are not going to put them on the existing controllers or hardware. All Readers need to be Wiegand readers. The external Doors will all get Axis A8207-VE MkII door stations, this will serve as the readers for those doors. 1. Install all door hardware and electrified locks on doors listed on floorplan. a. Run wiring for Axis A8207-VE MkII for reader and camera at all listed exterior doors. b. Mount and connect the Axis A8207-VE MkII door stations on exterior wall next to the doors on the side with the door handle, cabling will need to be run for these. c. Connect and power the electrified locks and test. 2. Install Wiegand readers on all internal doors as listed on floorplan. The secure side will need a request to exit button or a motion sensor. 3. Exterior doors will have a request to exit button on the inside, we are not going to use motion sensors on the exterior doors. The only doors that will get motion sensors to exit will be the interior doors.