Specifications include, but are not limited to: 1. Clear the project area of trees, brush, fences, buildings, and obstructions occupying space needed for construction. No building or structure partially encroaching on the right-of-way or located so as not to interfere with construction operations, shall be removed unless specifically noted on the Drawings or directed by the Engineer. 2. The installation of approximately 7,887± LF of 36” SS Main, 860± LF of 27” SS Main, 107± LF of 12” SS Main, and 52± LF of 8” SS Main utilizing an open cut method. 3. The installation of approximately 235± LF of 54” steel casing with 36” SS Main and 80± LF of 42” steel casing with 27” SS Main utilizing a jack and bore method. 4. The installation of approximately 1,473± LF of 30” HDPE SS Main and 446± LF of 42” HDPE SS Main utilizing a pipe bursting method. 5. The installation of approximately 48± sanitary sewer manholes, connection into the existing downstream sanitary sewer manhole, and re-connection of the existing sanitary sewers into the proposed sanitary sewer line.