Specifications include, but are not limited to: A. Consultant shall review all existing documentation provided in the RFP as well as review any additional documentation available by the Aspetuck Health Districts; B. Conduct a minimum of three deep test pits to evaluate the existing subsurface soils as well as determine average ground water elevation and ledge (if applicable); C. Provide falling head tests in each of the deep test pits to determine percolation rates; D. Prepare conceptual design that maximizes the leaching gallery capacity while taking into account percolation rates, ground water elevations, ledge, reserve area, and other regulatory requirements; E. Provide maximum daily flow based on conceptual design; F. Include any additional assumptions or clarifications to the conceptual design; G. Review available documentation of the Coleytown Middle School leaching field and site in combination with the Coleytown Elementary School and provide guidance regarding which agency (Aspetuck Health District, CT DPH, or CT DEEP) is likely to have jurisdiction over the permitting of the site; H. Advise on the maximum number of students the conceptual design can accommodate as well as the daily rate utilized for the calculation.