Specifications include, but are not limited to: 1. REMOVE AND LEGALLY DISPOSE OF THE EXISTING SKIRTING. 2. RELOCATE CLASSROOMS ACCORDING TO GSD INSTRUCTIONS AND GSD TIMELINE TO NEW SCHOOL SITES AND PLACE PER INSTRUCTIONS PROVIDED. 3. REMOVE AND LEGALLY DISPOSE OF THE OLD CONCRETE PIERS, WOOD FRAMING AND ANY DEBRIS FOUND UNDER A RELOCATABLE BUILDING AT THE LOCATIONS FROM WHICH THE BUILDINGS ARE BEING REMOVED. 4. CONTRACTOR MUST FURNISH, DELIVER AND INSTALL CONCRETE BLOCK FOR THE BUILDINGS TO REST ON AT THE NEW LOCATIONS. SINGLE UNITS WITH METAL FRAMES MUST BE SUPPORTED BY A MINIMUM OF 12 SUPPORTS AND WOOD FRAMES MUST BE SUPPORTED BY 16 SUPPORTS. 5. THE CONTRACTOR WILL BE HELD RESPONSIBLE TO REPAIR OR REPLACE, TO THE OWNER’S SATISFACTION, ANY PROPERTIES THAT ARE DAMAGED BY THE CONTRACTOR AS A RESULT OF THE MOVING PROCESS. 6. INSULATION UNDER BUILDINGS MUST BE TIED (SECURED) WITH TWINE OF SUFFICIENT STRENGTH AT A MINIMUM OF EVERY 16". 7. IF ANY STRUCTURES NEED TO BE MOVED IN SECTIONS, GSD WILL AID IN SECTIONING. SECTIONS MUST BE SECURED FROM THEFT AND WEATHER, BY THE CONTRACTOR, UNTIL ALL SECTIONS ARE IN PLACE AND CAN BE PUT BACK TOGETHER. 8. MOVE METAL RAMPS WITH BUILDINGS. RAMPS WILL BE DISASSEMBLED BY GSD, READY TO MOVE IN TWO (2) PIECES, A 5' X 5' LANDING AND A 5' X 26'+ RAMP. GSD WILL REASSEMBLE RAMPS AT THE NEW SITE. 9. WHERE POSSIBLE, BUILDINGS MUST BE SET AS CLOSE TO EXISTING GRADE AS POSSIBLE. DO NOT EXCEED 30" AT DOOR THRESHOLD WITHOUT GSD APPROVAL. 10. CONTRACTOR TO SUPPLY AND INSTALL “TIE-DOWNS” AS PART OF SET-UP AFTER BUILDINGS HAVE BEEN MOVED. 11. THE CONTRACTOR WILL BE RESPONSIBLE TO TRANSPORT BUILDINGS IN COMPLIANCE WITH ALL STATE AND LOCAL ORDINANCES INCLUDING ANY AND ALL COORDINATING WITH UTILITY COMPANIES, ETC. THAT MAY AFFECT THE SAFE AND TIMELY MOVEMENT OF SAID BUILDINGS AND FOR ANY AND ALL PERMITS REQUIRED TO LEGALLY TRANSPORT STRUCTURES. 12. CONTRACTOR IS RESPONSIBLE TO PROVIDE POLICE ESCORT SERVICES.