Specifications include, but are not limited to: New MCE Motion Control Engineering Ibox controller with the capability of delaying the shunt trip. New AC gearless Imperial machine New Gal restrictive clutch, door hangers, door rollers, interlocks and door rails New MOVFE 2500 linear door operator Replace all limit switches Replace compensation chain and compensation chain accessories in pit New wiring Traveling cable spares: The traveling cable for the elevator shall have no fewer than eight spare conductors or ten percent spare conductors, whichever is greater. Car station spares: a minimum of eight spare conductors shall be supplied to the car station from the machine room. Communication wire: one pair of shielded communication wires shall be provided for an emergency phone, and one spare pair of shielded communication wires shall be provided in the traveling cable to the car. Two Cat 6 stranded twisted cable, can be attached to the outside of the traveling cable. Other equipment spare wires: the number of spare wires shall be maintained regardless of other equipment installed inside the elevator at the time of installation, such as security card reader, camera, intercom, etc. Hoistway wire spares: There shall be no fewer than eight spare conductors from the elevator controller to the hoistway junction box Replace existing safeties and governor. Replace existing tail sheave. Replace the existing door safety edge with new Janus Panaforty New traction steel hoist ropes and governor ropes. New car and counterweight guide roller assemblies. Furnish and install a new Innovation control operating panel with code complaint fire service controls Must have new Innovation hall lanterns. Furnish and install new Innovation hall call stations Furnish and installed barrel-type, key-operated switches and keys EPCO1: for all switched or keyed equipment (e.g., lights, fan, independent service, EPCO 2: Run/Stop switch FEO K1: for all fire service Install car top safety rail Install an ascending car over speed/unintended movement protection device, such as a rope brake, on each elevator. Install hoistway access switch Code data plate: a data plate shall be provided by the elevator contactor that indicates the A17.1 Code to be used for inspections and tests. The data plate shall be such material and construction that the letters and figures stamped, etched, cast, or otherwise applied to the face shall remain permanently and readily legible. The data plate shall be in plain view, securely attached on the main line disconnect or on the controller. The height of the letters and figures shall be provided as per code. Load weighing system with cab display or alarm for overload Provide fire alarms interconnect for fireman’s return and fire hat service. Connection point will be provided in the elevator machine room by others Revisit and check hoistway and governor ropes after one year and shorten ropes if needed.