Specifications include, but are not limited to: The City of Canton Water Department, also referred to as the City, desires to initiate this agreement for a Turbine Service Pump Repair and Well Maintenance Program to serve the following purposes: • To perform required repairs to the Water Department’s high service pumps. • To clean existing water wells. • To perform required repairs to the well while it is out of service being cleaned. • To perform emergency repairs on an as needed basis The high service pump repair shall be performed as follows: 1) The high service pump is to be disconnected from the motor. It shall then be removed, disassembled, and cleaned for inspection. The City is to be offered the opportunity to inspect the disassembled pump. 2) The contractor shall provide the City with a written recommendation of pump repairs. 3) Any pump repairs authorized by the City are to be performed. 4) Possible repairs include: A. Overhaul of the discharge head and or any other worn plumbing shall include sandblasting to bare metal and repainting with epoxy compatible with potable water. The stuffing box bearing shall be replaced and the stuffing box re-packed. B. Each line shaft shall be cleaned and straightened. Maximum shaft run-out tolerance shall be 0.003”. C. The bearing retainer assembly shall be sandblasted and the line shaft bearing shall be replaced.