Specifications include, but are not limited to: 1. 2- 40’ x 8’ one-trip containers (or 4 20 ’ x8’ one-trip containers) 2. 1 ⅝’ steel studs w/ R13 Insulation walls and ceiling, drywall with texture and paint 3. Elastomeric silicone roof coating 4. Exterior painted with 2 part epoxy marine grade paint 5. Polyurethane caulk on doors and windows 6. Industrial grade zinc coating applied to all weld points 7. Drywall ceiling same as the wall in #2 with 3 ⅝” studs for thicker insulation 8. Commercial (high traffic) vinyl tile flooring 9. Electrical panel with space for all outlets and appliances outlets (Needs to be solar with ability to connect to conventional electrical power) a. 3 prong outlets (2 outlets per) in the office part installed between 3.5-4ft high above the work bench/desk and at normal heights along each wall. b. 3 prong outlets (2 outlets per) in the lab part installed at normal heights along each wall c. Outlets in the middle zone between the double entrance above doors for wall mounted fans 10. 2- Single zone 12k mini split AC units; 1 in each room 11. 8- LED lights with switches by the doors 12. 1- Partition retained container wall with two interior sliding glass doors to divide container into two rooms. 13. 1- Large capacity double stainless steel laboratory sink with detachable sprayer faucet compatible with external water tank/pump system (both hot and cold water accessible) plumbed through the wall 14. 1- 36” outswing steel external door - fire rated hollow core with steel jam 15. 1- 36” steel external door that swings inward- fire rated hollow ore with steel jam (doors keyed differently) 16. At least 7 double-pane double glazed windows with screens that can slide or hinge open 17. 2- Steel Entry Doors 3’ x 6’8” 18. 2- Sliding glass doors 8’ 6’8”