Specifications include, but are not limited to: Code Required Upgrades - 1. Widen two interior stepped aisles to 48” to meet ICC 300. 2. Install mid-aisle handrails at two interior stepped aisles to meet ICC 300. 3. Install two concrete landings and stairs to grade with handrails at grade exits of two interior stepped aisles to meet ICC 300. 4. Install side-mounted handrails at two perimeter stepped aisles to meet ICC 300. 5. Install two concrete landings and stairs to grade with handrails at grade exits of two perimeter stepped aisles to meet ICC 300. 6. Install handrails in two locations for each of two pass-through tunnels (total of four handrails) to meet ICC 300. 7. Installation of roof joist bridging for wind pressure to meet IBC 2018. 8. Installation of braces at cantilevered ends of roof to meet IBC 2018. 9. Provide additional anchorage of wood sill plates to concrete base to meet IBC 2018. 10. Provide structural stud backup at front roof fascia for wind pressure to meet IBC 2018. 11. Provide steel attachment plates and additional top plate along rear grandstand wall to meet IBC 2018 and ICC 300. Other Modifications - 12. Demolition and removal of two exterior grandstand bays which have weathered badly and are deteriorated. Some salvage of siding is required for reuse. 13. Removal of one partial row of grandstand seating previously constructed directly on grade without suitable foundation of pad, and reconstruction of grandstand front wall.