Specifications include, but are not limited to: Controller - TAC 32 Controller (Includes Options listed below) • 24 VDC Signal Voltage • Auto Light and Fan Feature • Car Independent Service • Car Traveling Lantern Circuitry • Door Bypass Operation • Electronic Door Detector Interface • Hoistway Access and Enable • THY Board - Solid State Starters (6 or 12 leads) 208 VAC - Battery Lowering in Controller - Viscosity Control (Required over 150 FPM) - eMax Monitoring Device Provisions Power Unit - New Submersible Power Unit: - New Oil - New Isolation Couplings - New Shutoff Valve Kit (Pump) - New Overspeed Valve - Viscosity Control (Required over 150 FPM) Jack - New Packing - Provide Pipe Stands for safe Pit Access Car - New Car Top Railing - New Toe guard - Fan: Two Speed - New Car Top Exit Switch - New Cab Wiring Hoistway - New HN Boxes (per each 2 cars, grouped) - Steel Tape with Mounting hardware, Selector and magnets (terminal limits included) - New Hoistway Duct Kit - New TAC 32 Field Friendly Wiring Package Includes single traveling cable, hoistway wiring, interlock wiring, interlock connectors, and serial wiring. Pit - New Shutoff Valve - New Pit Stop Switch - New Pit Ladder 12'' Wide