Specifications include, but are not limited to: · Seismic retrofit of select Concrete Masonry Unit (CMU) walls using a fiber-reinforced polymer (FRP) system · Seismic retrofit of select CMU wall-to-2nd floor connections using an (FRP) system · Seismic retrofit of select CMU wall-to-roof connections using structural steel framing and post-installed anchors. · Seismic retrofit of existing equipment, furnishings, decorative features, and other tall elements susceptible to overturning during a seismic event by providing adequate restraint to the existing walls and/or floors. · Seismic retrofit of mechanical and electrical elements susceptible to overturning during a seismic event by providing external restraint to the existing walls and/or floors. · Seismic retrofit of four (4) wall-mounted transformers in the Apparatus Bay by providing lateral bracing. · Seismic retrofit of a radiant heat system in the Apparatus Bay by providing lateral bracing. · Seismic retrofit of mechanical, electrical, and plumbing equipment exceeding 75 pounds located in-line with ducts or pipes by providing independent lateral bracing. · Seismic retrofit of unbraced gas pipes by providing lateral sway bracing. · Replace rooftop bearing pipe supports to include pipe clamps. · Seismic retrofit of existing suspended acoustical tile ceilings by providing conforming perimeter closure angles at minimum 50% of the enclosing walls. · Replace six (6) existing overhead doors with drift-compatible systems. · Seismic retrofit of a 32-foot-long region of exterior CMU screening wall located near the existing generator by providing out-of-plane wall bracing. · Restoration of removed roofing, walls, ceiling, and finishes to match existing.