Specifications include, but are not limited to: SEWER SERVICE- 4" CAST IRON PIPE Install a 4" cast iron sewer line from structure and connect to the public sanitary sewer system. Install clean-outs as required by local codes. Regrade yard in work area, sow grass see and spread straw to reestablish lawn. Contractor to supply and pay for all permits and road repairs. INSPECTION REQUIRED. IF FENCING IS MOVED, IT MUST BE REPLACED/RE-INSTALLED; ELECTRIC SERVICE -- 200 AMP Replace existing electrical service with a residential, 200 amp service. main disconnect, 110/220 volt, 24 circuit panel board, meter socket, weather head, service cable, and ground rod and cable. Seal exterior service penetrations to maintain a waterproof building envelope. INSTALL TO CITY OF LITTLE ROCK CODE; WEATHERPROOF RECEPTACLE Install a 15 amp, ground fault protected, surface mounted, weatherproof, PVC or non-ferrous box and receptacle using #14 copper Romex in EMT. Receptacle cover shall be permanently connected to box. INSTALL UNDER/NEAR ELECTRIC SERVICE PANEL