Specifications include, but are not limited to: Architectural, Interior Design, Mechanical, Plumbing and Electrical for a renovation near the entrance of the Ross Woodward School in New Haven, CT. The area being renovated consists of approximately 1,510 sq. ft. of an existing nurse’s suite in the principal’s suite, and adjacent areas on the first floor. The renovation will provide a new millwork in the south of the mail room, a new nurses’ room, in addition to a new health clinic comprised of a reception, medical exam room, dental room and an office. The scope of the work shall include demolition and new construction. Demolition includes interior partitions, flooring, millwork, lighting, and electrical. New construction will include interior partitions, ceiling, finishes, millwork, Mechanical, Electrical, and Plumbing rework. Architectural: In order to accommodate the new space requirements, the existing walls & doors to the nurses’ office, medical, dental and office will be relocated, which includes the ceiling, millwork and sinks to be relocated and new. The existing doors and lighting fixtures, and some millwork will be salvaged for reuse. The flooring within project scope will be new and of basic medical grade. A new reception and waiting area will be provided to accommodate control & egress to the clinic. Fire Protection: • Remove existing concealed sprinklers in existing ceilings noted to be removed on the Architectural Demolition drawings. Maintain existing sprinkler branch piping for new sprinklers. • Install new concealed sprinklers in new ceilings as shown on the Architectural new construction drawings. Connect new sprinklers to the existing sprinkler branch piping. Plumbing: • Remove existing sinks and faucets as shown on the Architectural Demolition drawings, remove all existing hot and cold water and vent piping back to the existing toilet rooms. Maintain these plumbing supplies for new connections. Remove underground waste piping as required. • Install new sinks in new locations as shown on the Architectural new construction drawings. Provide new hot and cold water and hot water return piping supplies to all new sinks. Provide all new vent piping for all new sinks. Connect all new hot and cold water and hot water return and vent piping to the existing plumbing systems located in the/near the existing toilet rooms. • Install new buried waste piping to serve all new sink locations. Connect to the existing buried waste pipe system. • Provide new countertop mounted emergency eyewash/drench hose in the new Medical room and new Dental room. Provide with a tepid water supply. Mechanical: • Remove existing ceiling supply and return diffusers, ductwork connections and accessories. • Remove and relocate control valve and hydronic, clean and reinstall existing enclosure • Pre-balance existing VAV-12. • Remove existing hydronic radiant ceiling panels, piping connections and accessories. • Rebalance existing supply and return diffusers to new CFM. • Rebalance existing VAV-12. • Provide new hydronic ceiling radiant panels and reconnect to existing supply/return piping. • Rebalance heating water supply and return piping connections. Electrical: • Existing light fixtures and exit signs to be removed and relocated. Provide new emergency twin head wall packs as shown on plan, reuse existing lighting circuit, extend as required. Provide new occupancy sensors and switches. • Remove and reinstall existing ceiling speakers, reuse back box and/or mounting accessories and extend all existing wiring to new locations. • Remove and dispose of all existing receptacles and tele/data outlets not indicated to be reused or replaced, provide new devices as per power plan. Provide new wiring for all new receptacles from existing panel board, reuse existing circuit breakers within panel board and provide new feeder rated ¾”C, 2#12, #12G feeder. For all tele/data outlets provide back box and conduit to above ceiling. • Remove and reinstall existing fire alarm horn/strobes and smoke detectors, extend existing wiring as required, provide new devices to match existing as shown on Power Plan. • Reuse existing feeders from demo prior to providing new home run from existing panel board (P19)-LFN1