Specifications include, but are not limited to: Optical Gas Imaging Infrared OGII) Camera for Gas Leak Detection, FLIR Gx320 - Primary Gas Seen Hydrocarbons (CxHx); Detector Type Cooled InSb; Spectral Range 3.2 µm to 3.4 µm; Resolution 320 × 240 (76,800 pixels); Quantification in Camera Yes; Thermal Sensitivity <10 mK at 30°C (86°F); Accuracy ±1°C (±1.8°F) for temperature range (0°C, to 100°C, 32°F to 212°F) or ±2% of reading for temperature range (>100°C, >212°F); Noise Equivalent Concentration Length (NECL) [∆T=10°C, Distance= 1 m]; Methane - 13 ppm-m; Minimum Laboratory Leak Rate (MLLR) [known gases]; Methane: 0.6 g/hr; Propane: 0.6 g/hr; Butane: 0.4 g/hr; Temperature Range -20°C to 350°C (-4°F to 662°F); Available Lenses 24° × 18° (23 mm); 14.5° × 10.8° (38 mm); Zoom 1–8× continuous, digital zoom; Focus Manual