Specifications include, but are not limited to: Item #1 - Siren; Qty: (3) Electro-mechanical, AC/DC Storm Warning Sirens; Omni-Directional – NON Rotating; Using one, 13 HP Continuous Duty, Fan Cooled DC Motor; dB Rating At 100 Feet: 127; Magnetic Contactor W/NEMA 3R Enclosure (Lockable); Optima 34U Rechargeable Batteries; Heavy Duty Battery Box (Pole Mountable and Lockable); Power Requirement: 230 VAC, Single Phase, 125 Amp; Telephone Pole Mounting Hardware; Item #2 - Radio Controller; Qty: (3) Radio Controlled Decoder; Four Functions, including cancel; Pre-Programmed; No proprietary software will be required for reprogramming of any feature of said decoder; Weatherproof Cabinet NEMA 4X (Lockable); Antenna; Must enable user reprogramming of function timing without the need for a computer connection. Item #3 - Utility Pole; Qty: (3) Class II Telephone Pole – 45-50 ft. AGL; Item #4 - Installation; Installation (Turn-Key); Bracken County, Kentucky shall supply only the following: siren sites, appropriate electrical service to the siren poles, all necessary permits, access, traffic control and electrical meters if desired. Proposer will be responsible for all other aspects of the “Turn Key” installation; Item #6 - Locking Mechanisms; All necessary padlocks to secure battery boxes, radio decoders, magnetic contactors, rectifiers, and electric disconnects.