Specifications include, but are not limited to: fabricate and install an aerial working platform per attached drawings and structural calculations. All fabricated steel for the working platform to be powder coated black. All safety rails and swing gate to be painted Behr 6 OSHA Safety Yellow or approved equal. Contractor to install a brass static grounding ball, unpainted, in an approved location near operator working space. Fiberglass grating to be black Grating Pacific T2515 or approved equal. Grounding ball to be an Eaton GCT2, or approved equal. All painting and welding must be done off-site except for touch-up. The contractor must pull all necessary permits and coordinate for inspection. No motorized personnel lifts will be allowed.