All correspondence must be made through the Vendor Portal. Specifications include, but are not limited to: CLASS A EXTERIOR WALLS- RATED FOR 115 MPH WIND LOADS STEEL BOTH SIDES OF WALL (S/S): 32 LF @ 8 FEET TALL ONE POUND DENSITY POLYSTYRENE CORE: EXTERIOR ROOF ¼:12 PITCH PANELIZED SHED ROOF W/ 9” OVERHANG: 96 SQUARE FEET DOORS 20 GAUGE INSULATED STEEL WITH 1/2 GLASS: 1 EACH WINDOWS EXTERIOR DIVIDER STRIP PICTURE WINDOW: 7 EACH Picture windows shall be nominal 3’8” wide X 3' high (Other sizes used and available to fit certain building sizes). They shall be installed 42" off the floor. A window will be glazed with 1/2” clear insulated tempered glass and shall be an integral part of the wall panel. The window shall be non-opening, and the entire window frame shall be painted by AAMA Specification 603.8. ELECTRICAL Will provide (1) wall switch preps, (4) duplex receptacle preps, (2) data, communications preps, and (1) 110-volt lay-in 2x4 LED fixtures (75 FC at desk height). Conduit and wiring are not included. This package shall meet NEC (current edition).