Specifications include, but are not limited to: .1.1 GENERAL 3.1.1.1 Vendor shall be responsible for delivery to the Equipment Division Buckhannon WV site. 3.1.1.2 Including net terms in the bid packet will result in disqualification. 3.1.1.3 Minimum capacity 980 gallons. 3.1.1.4 Minimum flow rate 100 GPM. 3.1.1.5 Shall be single wall underground minimum 7 ga thickness with lap fit and weld interior and exterior seams. 3.1.1.6 Tank shall be pressure tested. 3.1.1.7 Surface prep SSPC-SP 10 blast interior surfaces, SSPC-SP 6 blast exterior surfaces. 3.1.1.8 Exterior coating Polyurethane minimum 75 MILS. 3.1.1.9 Interior coating Chemthane 4200PW 15 MILS DFT. 3.1.1.10 Operating pressure shall be atmospheric. 3.1.2 Provided Equipment 3.1.2.1 6” SCH 40 pipe stub Inlet. 3.1.2.2 6” SCH 40 pipe stub Outlet. 3.1.2.3 2” HC vent. 3.1.2.4 24” Manway for stackable riser. 3.1.2.5 6” SCH 40 transfer pipe. 3.1.2.6 Striker plate. 3.1.2.7 Sludge baffle minimum 7 ga. 3.1.2.8 Underflow baffle minimum 7 ga. 3.1.2.9 6” 45-degree diffusion elbow. 3.1.2.10 Full bulkhead minimum 7 ga. 3.1.2.11 2” opening for air circulation. 3.1.2.12 36” grade -level manway shipped loose. 3.1.2.13 24” pvc cover. 3.1.2.14 (two) 2-24” x 12” stackable riser pre-assembled. 3.1.2.15 (two) 2- 24” x 6” stackable riser. 3.1.2.16 Stackable riser adapter ring and gasket. 3.1.2.17 Stackable riser safety screen. 3.1.2.18 Removable diffusion baffle 7 ga. 3.1.2.19 12” x 12” wear plate- ¼” 3.1.2.20 (two) 2- cda-15 concrete Deadman. 3.1.2.21 (two) 2- polyester hold-down straps.