Specifications include, but are not limited to: 1. Provide Pre-engineered steel building package to our facility 79554 Hwy202 Seaside Oregon 97138 2. Provide stamped design and layout 3. Column base and anchor bolt report 4. Roof Panels 24 gauge, mechanical seams 5. Side panels and trim 26 gauge 6. All panels and trim shall be Kynar paint. 7. Building size 60’ x 150’ x 20 ft eave height with 3:12 pitch 8. 2-16 x 16 overhead door openings as per design 9. 6-14 x 14 overhead door openings as per design 10.1 interior partition wall as per design 11.1 interior man door as per design 12.2 exterior man doors as per design 13.Gutters and down spouts 14.Steel building package only, foundation and overhead doors supplied by others. 15.Building code requirements: • Snow Load 38 PSF Ground • Wind 96 MPH 3 Second Gust • Exposure C • Seismic D