Specifications include, but are not limited to: 1. Provide and furnish all necessary labor and materials in connection with the addition of a truck bay on the North end of the station. 2. This Includes: a. Ground Prep b. Cutting existing asphalt c. Compacted gravel d. Perimeter drainage e. Asphalt patching as needed f. Concrete Drain g. Concrete slab with 10” curb h. Concrete reinforcing – OH Door nosing – 5/8 x 12” Anchors i. Pressure treated plates – Sill seal and Galvanized anchors j. 6 mil poly vapor barrier throughout k. 2x6x16 KD Wood framing walls including plates & truss bracing l. 16’ Overhead door header m. 1x3x14 strapping of interior/exterior walls n. 4x8x5/8 Advantech Roof – 4x8x16 Zip sheathing walls o. Pre-Engineered Truses 8 Regular and 1 gable p. Wall Insulation 16” x 6” R19 q. Roof Insulation 24” x 12” R38 r. 14’ x 10’ OH Door s. 1 – Man Door t. Exterior 26 Ga Metal siding and trims u. Asphalt Roofing and Underlayment – Shingles v. Interior Metal wall and ceiling trims w. Electrical lights, switches and outlets to match existing building x. Moving of electrical service including a generator transfer switch.