Specifications include, but are not limited to: 15660E MSRP - METAL CAGE (COMPRESSOR): All openings shall be sealed or capped that can collect water EA 15-651 MSRP - 2.0 - CENTRAL HEATING and AIR CONDITIONING SYSTEM, COMPLETE : 15-651: Contractor shall calculate the proper size of all HVAC equipment and materials. Install/Replace a Central HVAC system with a properly sized, high efficiency (14 SEER), Central heating and air conditioning unit per specifications. The contractor is responsible for all permits, green tag, duct sheet & inspection form and manual Js. Installation shall include removal of existing system and all its components and shall be replaced with new parts and equipment. GC shall provide a 3 year service agreement. Enter tonnage of unit as units of measure. All materials and/or equipment demolished or repaired containing refrigerants, refrigerant oils or its by products are considered hazardous and belong to the General Contractor and shall be removed off the premises. Comments: contractor resposible for gas and elec service to new unit EA 15-651E MSRP- MANUAL J: Contractor selected by the homeowner must provide an ACCA approved Manual J to the Housing Inspector prior to closing. The Contractor submitted Description of Services will be adjusted to meet the Manual J requirements EA 15660H MSRP - PULL-DOWN STAIR/DOOR: 1"X6" stiles & treads: Install or Replace attic ladder, installation shall not disturb more than the lead base paint de minimis levels of 2 square feet per room or space of overall project or jobs EA 00-000 GENERAL CONDITION: Comments: plumbing contractor to secure elec wires to bottom of floor joist or beam bottoms PU 18-000 MSRP-LEAD-BASE PAINT, CLEARANCE: GC shall adhere to 24 CFR Part 35 Sec. 35.1340 (Clearance) EA 18-000 MSRP-LEAD-BASE PAINT, PAINT TESTING: GC shall adhere to 24 CFR Part 35 Sec. 35.1320 (a) (Paint Testing) EA 18-000 MSRP-LEAD-BASE PAINT, SAFE WORK PRACTICES : GC shall adhere to 24 CFR Part 35 Sec. 35.1350 (Safe Work Practices) EA