Specifications include, but are not limited to: MASTER VALVE BOX, COMPLETE UNIT: Replace / Install. SEWER, DOUBLE CLEAN OUTS, COMPLETE UNIT: Install and meet specification #02220 (Excavationg & backfilling of holes). . MSRP - GAS SERVICE LINE, COMPLETE Install/Replace pipe from meter to house.: 15-442F: Replace/Install gas line from meter to structure in accordance to 15-442 & meet specification #02220 (Excavating, proper compacting and back-filling holes or trenches included .MSRP - ELECTRICAL-SERVICE PANEL - 200 AMP: 16-600J: COMPLETE with green tag. (Install/Replace). Installation is to include 200 amp service panel, meter box, service mast, mast head ,etc. and sealing of all holes and penetrations such as flashing and sealant. Installation will include re-connection fee. Permit must reflex the actual work being performed such as electrical panel (service upgrade, etc.). These can be indicated under the notes section on the online application. All materials and/or equipment demolished or repaired are considered salvage and belong to the homeowner for use or disposal unless the homeowner relinquishes salvage rights to the contractor (Contractors Bid Accordingly). The contractor must remove all unwanted material and debris. MSRP - DWV, COMPLETE SYSTEM: 15-303: Installation to include removal of entire existing DWV system; to include p-traps to bottom of sink drain. To include proper strapping to floor joist, Clean outs and the vent stacks must protrude to the exterior of the dwelling with proper new flashing. If contractor cannot remove a vent the Housing Inspector must approve the use of a mechanical vent prior to installation otherwise contractor maybe subject absorbing the cost of that opening. All wall, ceiling and roof penetrations must be properly sealed. Enter (OP) for openings. All materials and/or equipment demolished or repaired are considered salvage and belong to the General Contractor for use or disposal. T & P VALVE, COMPLETE UNIT: Install/Replace. MSRP - WATER RE-PIPE, COMPLETE UNIT: 15-430: Install/Replace water supply re-pipe with new copper or PEX. Contractor to reference Section 15-Plumbing (15-015) and all applicable specifications under this section. Installation to include 1/4 turn angle stops were applicable and full port ball valves were applicable. New lines will run to and connect to all appliances and fixtures MSRP - GAS RE-PIPE, COMPLETE SYSTEM: 15-442E: Installation to include approved gas stops and flex lines to appliance MSRP - 2.0 - HVAC WITH GAS FURNACE, COMPLETE TO INCLUDE PLUMBING AND ELECTRICAL GREEN TAGS WHEN APPLICABLE: 15-651: Install/Replace a Central HVAC system with a gas furnace. The unit will be high efficiency (14 SEER), sized according to Manual J and meet or exceed Section 15- Mechanical specifications. GC shall provide an 18 month service agreement. All materials and/or equipment demolished containing refrigerants, refrigerant oils or it¿s by products are considered hazardous and belong to the General Contractor and shall be removed off the premises. Contractor, list equipment to be installed.