Specifications include, but are not limited to: The contractor’s bid must include the following: 1) Demolition of the existing foundation 2) Extension of all utilities (electrical , water, sanitary sewer and natural gas) 3) Construction of a platform for the HVAC condenser capable of securing a 400lb load 4) Installation of an insulated subfloor system, (Including R-30 Batt insulation, ½“ plywood, primer and two coats paint) 5) Construction of two (2) 4’ wide entry stairs for front and rear entry with treated lumber, risers, treads, handrails, hangers and fasteners. Landings and porches may be required as well and must be constructed in accordance with all applicable code. 6) Installation of lattice (if elevation is less than 4 feet) or installation of board & batten skirting system with flood vents (if elevation is greater than 4 feet). Lattice or board & batten skirting system must consist of treated framing, fasteners, primer and two coats paint. 7) Clearing and grade leveling. Dirt should be level to drain (fill as needed) and no more than 4” spacing to bottom of lattice framing and 0” spacing to bottom of board and batten skirting.