Delivery of the following parts to Edwards AFB, CA. Equal to listed parts is acceptable. This is a total small business set-aside. Award will be made based on "best value to the government." To be considered best value, the items must be technically acceptable, quantities requested per each item listed in the description must be included in your quote.
1.) Qty 23,000 ft, Coaxial Cable, corrugated copper, 7/8 in, black PE jacket (Halogen free jacketing non-fire-retardant) tested C-Band and CBRS qualified Comparable to CS-ANDREW Part #10317390, 520093702/00 AVA5P-50-C
2.) Qty 2,000 ft, Superflexible Foam Coaxial Cable, corrugated copper, 1/2 in, black PE jacket (Halogen free jacketing non-fire-retardant) Comparable to CS-SYSTIMX Part #FSJ4-50B, FSJ4-50B CGDSFSJ450B ROHS
3.) Qty 150 ea, Type N Male EZfitfor 7/8 in FXL-780 Comparable to CS-ANDREW Part #78EZNM, 78EZNM FXL-780 N TYPE MALE EZFIT SMOOTHWALL ALUMINIUM 7/8" STRAIGHT CONNECTOR
4.) Qty 150 ea, Type N Female EZfitfor 7/8 in FXL-780 Comparable to CS-ANDREW Part # 78EZNF FXL-780 N TYPE FEMALE EZFIT SMOOTHWALL ALUMINIUM 7/8" STRAIGHT CONNECTOR
5.) Qty 80 ea, SureFlexJumper with interface types N Male and N Male, 1.829 m Comparable to CS-ANDREW Part #468825, L4A-NMNM-6-P LDF4-50A SUREFLEX JUMPER WITH INTERFACE TYPES N MALE AND N MALE, 1.829 M
6.) Qty 140 ea, High Power Lightning Protector 1.5-700 MHz, Broadband HF/VHF/UHF gas tube coaxial protector with multi-strike capability for general radio use. Comparable to Part#460697, POLY TRANS IS-50NX-C0 RF SPD 1.5MHZ-700MHZ 50 KA
7.) Qty 56 ea, Mastic Tape Compound 2229, 3-3/4 in x 10 ft, Black, 1 roll/carton, 8 rolls/Case Comparable to Part #420718, 3M ELECT 7000043008 2229-3-3/4X10; SCOTCH-SEAL MASTIC TAPE, 2229, BLK, 125 MIL 3 3/4 IN X 10 FT
8.) Qty 1,000 ft, THHN/THWN-2 Cable, 6 AWG, 19 Strand, 600V, Annealed Copper, PVC Insulation, Nylon Jacket, Green Comparable to WESCO Part #6G-0601-04, 6G-0601-04
9.) Qty 1,000 ft, THHN/THWN-2 Cable, 6 AWG, 19 Strand, 600V, Annealed Copper, PVC Insulation, Nylon Jacket, Black Comparable to WESCO Part #6G-0601-02, 6G-0601-02
10.) Qty 8 ea, Grounding & Bonding, Bus Bar, 4" x 16",8D, 8DB Comparable to Hubbell Part #938530, HBBB14416H BUSBAR,4"X16",8DA 8DB,INSLTR
11.) Qty 28 pk, Dual Rated, Aluminum/Stranded Copper Conductor, 14 to 2/0 AWG Conductor Comparable to T&B ADR21 AL CONN 2/0-14 AWG (25 EA PER PACK)
12.) Qty 125 ea, SureGroundGrounding Kit for 7/8 in coaxial cable Comparable to CS-ANDREW Part #SG78-06B2A, ANDREW SUREGROUND KIT AVA5 7/8" GROUNDING KIT 600MM / 24" BLACK
13.) Qty 10 ea, Heat Shrink Thin-Wall Tubing FP-301-1-Clear-100`: 100 ft spool length, 300 linear ft/box Comparable to 3M Elect Part # 7100019710 FP-301BS-1-CR;HEAT SHRINK THIN-WALL TUBING, FP-301, CLEAR 1IN (2.54 CM)
14.) Qty 300 ea, Type N, female (jack), straight, EZ style connector for LMR-400, TCOM-400, and T-RAD-400-FR type cables Comparable to TIMES MICR Part #EZ-400-NF-X, TYPE-N FEMALE JACK 50 OHM CRIMP SLEEVE FOR LMR-400 NO BRD TRIM