Amendment 0003:
The purpose of this amendment is to incorporate changes to the specifications and drawings into the solicitation.. All other terms and conditions remain unchanged..
See attachments "W9128F23B0014 Amend 0003", “M-104 Am-0003”, “40 17 30.00 40 Am-0003”, and “01 12 00 Am-0003”.
Amendment 0002:
The purpose of this amendment is to incorporate FAR 52.217-5, FAR 52.217-8, and FAR 52.217-9 clauses into the solicitation. All other terms and conditions remain unchanged..
See attachment "W9128F23B0014 Amend 0002"
Amendment 0001:
The purpose of this amendment is to change the ProjNet Bidder Inquiry Key from XZ9UGM-IZ7X9K to 6U579S-XYI3CR.
See attachment "W9128F23B0014 Amend 0001"
----
Project Description:
Omaha District is interested in replacing the current four compressor configuration with two larger 2-stage rotary screw, oil-less compressors for the purpose of reducing maintenance and increasing system reliability. The project will aim to decrease the systems recovery time by increasing the compressors capacity (CFM) and the total system storage. This will be accomplished by replacing one damaged accumulator tank and adding two additional accumulator tanks as well as replacing the undersized air supply piping. This will allow two units to go into condensing mode quicker and provide the Big Bend personal the ability to conduct multiple make-up air counts during the condense blow-down cycle as there are typically multiple units operating in order to maintain 100 psi system pressure.
An optional back pressure system will also be included.
The Contractor will be required to commence work upon receipt of contract award and complete the work 365 calendar days after receipt of Notice to Proceed, this is subject to change after solicitation issuance.
Estimated Construction Costs (only include if applicable):
The estimated construction cost of this project is between $500,000 and $1,000,000.
NAICS Code:
The Primary North American Industry Classification System (NAICS) code anticipated for solicitation is 238290 - Other Building Equipment Contractors, with a size standard for Small Business of $22M.
Contracting Office Address:
USACE Omaha District
1616 Capital Ave, Omaha, NE 68102-4901
Point Of Contact:
Technical inquiries and questions relating to this solicitation shall be submitted via Bidder Inquiry in ProjNet at
https://www.projnet.org. See "W9128F23B0014_Solicitation" for Project ID and Bidder Inquiry Key
Place of Performance:
BIG BEND DAM POWERHOUSE,
SD-47, 33573 NORTH SHORE RD
FORT THOMPSON SD 57339
Note: Offerors please be advised that an online registration requirement in System for Award Management (SAM) database http://www.sam.gov/ exists and directed solicitation provisions concerning electronic annual Representations and Certifications on SAM. Representations and certifications are required to be up-dated annually as a minimum to keep information current, accurate and complete