**This is not a Small Business Set Aside**
References:
U. S. Coast Guard Coatings and Color Manual, COMDTINST M10360.3D (January 2014)
U. S. Coast Guard Surface Forces Logistics Center Standard Specification 6310 (2020), Requirements for Preservation of Ship Structures
Requirements:
Provide authorized coating systems per SFLC Std Spec 6310, Appendix C, which meet the requirements of Table 1 below. For each system, assume a 30% loss. For systems which require stripe coat(s), assume that that 20% of the volume required for a full coat is required for a stripe coat. Colors for primer and intermediate coats must be in accordance with CIM 10360.3D. All multi-coat systems, including stripe coats, must be in contrasting colors for application.
Table 1 – List of Coating Systems, Coverage, & Topcoat Color
System per SFLC Std Spec 6310, Appendix A
Coverage (Sq. Ft.)
Description of Paint:
1. Smoke Stack (Smoke Stack Casing, Steel Exterior) (Stack Preservation)
6,000
White 17925
2. Smoke Stack (Smoke Stack Casing, Steel Exterior) (Stack Preservation)
2,000
Black 37038
Proposal Submission Requirements:
For each system, identify for each coat, and include calculations as applicable:
- Manufacturer
- Product
- National Stock Number or Part Number, as applicable
- Color
- Volume Solids
- Dry Film Thickness
- Theoretical Coverage (Sq. Ft./Gal)
- Practical Coverage (Sq. Ft./Gal) – apply loss assumption here
- Coat Gallons
- Stripe Coat Gallons – apply stripe coat assumption here, if stripe coat is required
- Total Gallons (Coat + Stripe Coat)
- Number of Product Kits
See the Appendix for an example presentation of the above information.
For each product, submit a Product Data Sheet.
Delivery Requirements:
Include delivery to Honolulu, HI by 15 February 2023.