Specifications include, but are not limited to: 1. Removal of approximately 6,800 square feet of existing low-sloped standing seam metal roof over a metal frame. 2. Removal of approximately 4,300 square feet of existing low-sloped modified bitumen membrane roof system to plywood deck. 3. Removal of existing roof vents, existing metal flashings, and existing gutters and downspouts. 4. Installation of a new underlayment on existing plywood deck. 5. Installation of approximately 11,100 square feet standing seam metal roof including metal flashings, trim and curbs. 6. Installation of new gutters and downspouts. 7. Installation of new flashings at vents and flue. 8. Installation of new blocking, plywood liner, base and cap flashing on existing parapets.