Specifications include, but are not limited to: demolish existing roof mounted exhaust fans (abandon ducting in-place) and associated electrical; demolish existing boiler stack and plumbing vent and reroute through sidewall and gable end wall, install new sidewall mounted intake and exhaust fans (qty. 2) plus associated electrical, remove existing single skin metal roofing and replace with standing seam insulated metal panel roofing according to manufacturer’s instructions. All materials are to be provided by the successful bidder. 1 Mobilization and Demobilization Lump Sum 1; 2 Demolition of Existing Roof Lump Sum 1; 3 Demolition of Mechanical Systems Lump Sum 1; 4 Demolition of Electrical Systems Lump Sum 1; 5.1 Furnish Standing Seam IMP Roof Panels Square Foot 10,533; 5.2 Install Standing Seam IMP Roof Panel System Lump Sum 1; 6 Installation of New Mechanical Systems Lump Sum ; 7 Installation of New Electrical Systems Lump Sum 1;