Specifications include, but are not limited to: A. Requirements for All Doors: 1. Accessibility: Comply with ANSI/ICC A117.1. 2. Grade: ANSI A250.8 – Level 3 and Physical Performance Level B, Model 2 (seamless/ fully welded). 3. Thickness: 1-3/4 inches. 4. Door Design: In accordance with SDI 106, Design N, Narrow Lite. 5. Door Top and Bottom: Close with inverted 14 gage minimum end channels or closures. 6. Door Edge Profile: Beveled on both edges. 7. Door Reinforcement: Comply with ANSI A250.8. Reinforce for surface applied hardware. 8. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated. 9. Hardware Preparation: In accordance with DHI A115 Series, with reinforcement welded in place, in addition to other requirements specified in door grade standard. 10. Galvanizing: All components A40 hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A 653/A 653M, with manufacturer’s standard coating thickness. 11. Finish: Factory primed, for field finishing. 12. Texture: Smooth faces. B. Exterior Doors, Non-Fire-Rated: 1. Core: Polyurethane 2. 14 Gage Minimum C. Interior Doors, Fire-Rated: 1. Fire Rating: a. Provide units listed and labeled by UL. b. Attach fire-rating label to each fire rated unit