Specifications include, but are not limited to: The Work of this approximately 13,900 sq. ft., Business (higher education) occupancy, construction type VB Project is defined by the Contract Documents and includes, but is not limited to, the following: The structural system includes concrete shallow spread foundations and concrete floor slab on grade, with a light steel structural frame and some stud bearing walls supporting a metal roof deck. Exterior walls consist of insulated metal stud framing, and exterior sheathing with an EIFS finish on the exterior and painted gypsum board on the interior. Fenestrations include glazed aluminum storefront and curtain wall assemblies. Roofing will be a TPO single-ply membrane on lightweight insulating concrete sloped for positive drainage. Interior construction includes gypsum board-clad metal stud partitions, acoustical panel ceilings with sound absorbing ceiling acoustical panels, and acoustical clouds. Floor finishes include carpet, textile composite flooring, resilient rubber sheet flooring, and ceramic tile. Interior door openings include wood doors in hollow metal door frames and glazed aluminum doors and frames. Specialty acoustic considerations will be necessary around the sound stage and classroom stud wall and ceiling construction with specialty sound / vibration isolation components and an alternate recessed isolated slab. Landscaping consists of an underground irrigation system and drought tolerant vegetation