Specifications include, but are not limited to: 1 369 Square Feet Exterior Beam Section: 27" Prestressed Concrete Box Beams (3' Wide). 2 Beams at 61'-6" Overall Length. Skew = 30° Left Forward 2 1107 Square Feet Interior Beam Section: 27" Prestressed Concrete Box Beams (3' Wide). 6 Beams at 61'-6" Overall Length. Skew = 30° Left Forward 3 14 Each 1-13/16" Elastomeric Laminated Bearing Pads (60 Duro Hardness) B1 pads (4-3/4" x 28") 4 4 Each 1-13/16" Elastomeric Laminated Bearing Pads (60 Duro Hardness) B2 Pads (4-3/4" x 15-1/2") 5 16 Each 1" Diameter x 2'-0" Swedged Anchor Bolt or No. 8 Deformed Reinforcing Bar (Grade 60) Galvanized 6 34 Square Feet 2-1/8" Thick Sponge Rubber Preformed Joint Filler at Bearings 28.3 LF @ 5-3/8" Wide = 12.7 SF/End, 26 SF Total 9.1 LF @ 4-3/4" Wide = 3.6 SF/End, 8 SF Total 7 128 Square Feet 1" Thick Sponge Rubber Preformed Joint Filler at Beam Ends 28.3 LF @ 27" Wide = 63.7 SF/End, 128 SF Total 8 20 Each Guardrail Attachment Assembly for Box Beams with Studs, Nuts, and Washers 9 143.5 Linear Feet 1" Diameter Post-Tensioning Thread Bar w/14 Hardened Nuts 4 Bars @ 27’-6” and 2 bars @ 16’-9” 10 10 Each Bearing Plate 9"x9"x1" 11 2 Each Bearing Plate 5"x5"x1-1/4" 12 20 Each Type TL-2 Bridge Guardrail Posts 13 132.5 Linear Feet Type TL-2 Bridge Guardrail 14 430.5 Linear Feet 1 Inch Grout Stop 15 34 Each 1"x8"x8" Washer, with a 3-1/2” diameter hole in the center.