Specifications include, but are not limited to: 1. DEL MEDICAL OTC18M BUNDLE • Minimum source to ceiling distance 32.6 (830 mm) • Vertical telescope travel range (Manual only): 70.8 (1800mm) • Longitudinal travel range: 136.4 (3460mm) • With optional rail extensions: 222.2 (5645mm) • Longitudinal detent positions, configurable during installation • Transverse travel range, with standard 9.8' (3m) rail: 84.6 min. (2150mm) with optional 13.1' (4m) rail: 137.8 max. (3500mm) • Transverse detent positions, configurable during installation • Tube rotation range, horizontal axis, -120°, +120° • Detent positions, horizontal axis, -90°, 0°, +90° • Tube rotation range, vertical axis, -154°, +182° • Detent positions, vertical axis, -90°, 0°, +90°, +180° • Vertical telescope travel range: 70.9 (1800mm) • Front display digital readouts: SID, horizontal tube rotation angle, receptor and generator techniques selections, and collimator information (when paired with auto collimator) • 1 pair 80' (24 meters) HV cables included with cable concealment and management system • Standard 14' rail included 2. SIEMENS MANUAL COLLIMATOR (ML03) Item Includes: • Lamellae close to the source to shield off extra focal radiation • Bucky light generated by laser guarantees a sharp light line for all source to image distances • Rotation by +/-45° with a stop in 0° position by swiveling flange • Tape measure integrated in a user-friendly way in the collimator • Two (2) foam protected accessory rails facilitate attachment of additional devices and further filters • LED powered light field for better contrast and greater lifetime 3. DR 65kW 3-PHASE GENERATOR • 150 kVp • Digital Interface for integration with the digital radiography systems • Anatomical programming with 768 programmable technique selections • One, two, or three point technique selection • Two Bucky capability • Power cabinet with auxiliary power supply • Tube protection circuitry • Dual speed starter • Integrated service software assists in calibration and service • Self-diagnostic circuitry with error code recording for fast trouble shooting 4. CANON E254FX TUBE • 90° cable arms, 0.6Xl.21\11v1 FS, 400KHU, 150KVP, 12° Target, 4" Anode 5. VS300WALLSTAND Del Medical CS300 Wall Stand • Slender Column Design • Electric Fail-Safe locks only require power to move column • Ergonomic release handle • Lateral patient handgrips included (standard) • Height: 84 in. (213.4cm) (includes vertical travel) • Depth: 13.4 in. (34cm) • Width: 24.6 in. (62.5cm) • Weight (with receptor): 200 lbs. (91kg) • 0.4mm front panel aluminum equivalency